![3par ssmc change raid type 3par ssmc change raid type](https://d8tadude.com/wp-content/uploads/2019/12/2-SSMC-Topology-Insights-740x268.png)
The range is 0.5 MB to 4 MB and the default value is 3 MB. If disabled, new RAID-0 CPGsĬannot be created on this system. The default is 'no'.Įnables or disables support for RAID-0. HP strongly recommends RAID-6 for high capacity NL drives. Ifĭisabled, new RAID-5 CPGs cannot be created on NL drives. can be 'yes' orĮnables or disables support for RAID-5 on NL drives. Until 'setsysmgr export_vluns' is issued. Ifĭisabled, vluns and host ports will not become active after a reboot The default is 'yes'.Įnables or disables automatically exporting vluns after a reboot. If enabled, automatic failover is triggered Maximum length is 127 characters.Įnables or disables the automatic failover of target ports to theirĭesignated partner ports.
![3par ssmc change raid type 3par ssmc change raid type](https://hpe-developer-portal.s3.amazonaws.com/uploads/media/2018/9/add_authorization-1538420815894.jpg)
Spaces, enclose the value inside double quotes. Sets a note that will be displayed when checkupgrade is run. To disable setting the volume retention time in the system, enter 0 Providing either the 'd' or 'D' for day and 'h' or 'H' for hoursįollowing the entered time value. is a positive integer value and in the range of 0 -Ĥ3,800 hours (1825 days). Specifies the maximum value that can be set for the retention time ofĪ volume. Minimums), Maximal (one disk's worth in every cage), and Custom (not Valid values areĭefault (roughly 2.5% with minimums), Minimal (roughly 2.5% without Sets the sparing algorithm used by admithw command. Sets the IP address of the system to which events will be sent as syslog
![3par ssmc change raid type 3par ssmc change raid type](https://cdn.slidesharecdn.com/ss_thumbnails/3par-vmware-vmug-nyc-1233269677187368-3-thumbnail.jpg)
The syslog messages are sent with a facility user and withĮvent severities mapped to syslog levels such as: A value of 0 disables the message, and a value of 1 enables the Performs the same function as RawSpaceAlertFC, but should be used forĮnables or disables sending events as syslog messages to a remote
![3par ssmc change raid type 3par ssmc change raid type](https://rsavage367055661.files.wordpress.com/2018/08/ssmcsplash.png)
When the total space on the availableĬhunklets (both clean and unclean) for the specified drive type fallsīelow the specified value, the alert is posted. Sets the user configurable space alert threshold (10 to 100000 GB) forįibre Channel type drives. The following parameters can be configured on the system and are issued for Specifies any additional information for the system. Specifies the contact information for the system. The following options allow annotation of system with descriptor information: Specifies the new name of the system up to 31 characters in length. The following option is for changing the name of the system: System-wide parameters such as the raw space alert. The setsys command sets properties of the system, including options toĪnnotate a system with descriptor information such as physical location, It should be noted that the setsys command can also edit other values, I’ve included the help output below for reference. Populate the fields with your desired information and click ‘OK’.Click on the dropdown menu next to the array name and select ‘Settings’.Click the ‘3PAR StoreServ’ menu in the top left corner.If you have deployed the 3PAR StoreServ Management Console web client you can use the following steps to configure the settings. Populate the desired fields and click ‘OK’.Right click on the array and select ‘Edit System’.If we now run the showsys command again we see that the fields have been updated 3PARLAB2 cli% showsys -dĬonfiguring via the GUI is simple as always.
#3par ssmc change raid type update
It’s easy to update this information using the setsys command setsys -name 3PARLAB2 -loc "The Grid" -owner ByteSizedAlex -contact "Alex Bytes" -comment "Everything Is Awesome" Under the ‘System Descriptors’ section we can see some useful fields that are empty. SSH to the array you wish to configure and use the showsys command with the –d switch (details) to see what information is currently configured. CLIįirst let us take a look at the CLI options. This can be achieved using either the CLI or GUI interfaces. Having previously deployed our 3PAR simulators ( ESXi, Workstation, RCIP Config) for lab work it’s time to update the system information on them. Most systems have data fields which can be populated with useful information and the HP 3PAR is no exception.